Operation procedure of horizontal split casing pump - Operat

         A The operator must known operation procedure of the horizontal split case pump 

B horizontal split case pump how to working in the pump room .

1, the preparatory works before starting the pump : check whether the suction/ drainage pipes and valves are in good condition; check whether switch of the pipe valve is flexible ; check whether float of the water level is flexible; check  whether oil in the bearing is appropriate; check  whether the gland box is normal; rotation of the coupling with hands whether have friction noise; check whether the vacuum pump water diversion system is in good condition;check  whether the power supply equipment, electrical switches, motor is normal.

2, starting the pump: open the valve on the suction pipe  , close the drain valve, open the vacuum pump suction and exhaust valve, open the vacuum pump(water from the vacuum pump does not contain white,close the vacuum pump); according to electrical operating procedures, close the switch corresponding motor control ; After the pump speed is stable, open the valve on the pressure gauge, then the pressure gauge reading should be gradually increased, if the pressure gauge reading does not rise, the pump is not working normal, should turn off the motor, re-inspection and diversion; when the pressure gauge readings To 0.4MPA, you can slowly open the drain valve, then the pressure gauge reading should be reduced, the vacuum gauge reading should be increased, if  with the above does not match, should be promptly identified original sin off the vacuum pump; pay attention to the water level gauge, adjust the drainage valve, The water level remains normal.

3, stop the pump: close the drain valve; close the vacuum pump, pressure gauge and valve; turn off the motor.

 